Siebel Administration >  SBL-SMI-00116: The minimum number of multithreaded server processes (%1) cannot be larger than the maximum number of multithreaded server processes (%2)

SBL-SMI-00116: The minimum number of multithreaded server processes (%1) cannot be larger than the maximum number of multithreaded server processes (%2)

This error message is reported in a server components log file when it has incorrect values/settings for two of its parameters – MinMTServers and MaxMTServers, where the former happens to be larger than the latter.

Cause

The minimum MT server setting cannot exceed the maximum MT server settings. If it is incorrectly set up that way the above error message will be reported when the component attempts to start up.

Diagnostic Steps

Identify the settings for the following parameters for the said component:

MinMTServers

MaxMTServers

Solution

Ensure that the MaxMTServers is more than MinMTServers. Once the parameters have been updated, restart the Siebel server services for changing to take effect.